Shop by Department

Shop By Brand

    Hospital And Physician Supplies






      Home > Hospital And Physician Supplies > Equipment & Furnishings > Equipment > Exam & Diagnostic > Welch Allyn Diagnostic Sets >

    Welch Allyn 3.5V AutoStep Coaxial Ophthalmoscope-1 Each
    Welch Allyn 11730


     
    Alternative Views:



    Price: (Members Only)
    Brand : Welch Allyn
    MPN # : 11730
    Packaging: 1 Each


    Availability: Ship within 24-48 Hours
    Product Code: 11730
    :

     
    Welch Allyn 3.5V AutoStep Coaxial Ophthalmoscope-1 Each

    Patented Welch Allyn Coaxial Vision optics, combined with 68 lenses in single-diopter steps, for the precision you need to conduct a quality eye exam.

    Features :-

    Halogen HPX lamp illumination for true tissue color
    18 unique aperture/filter combinations for greater versatility
    Polarizing filter virtually eliminates corneal reflection
    68 lenses in single-diopter steps for precise resolution (+38 to -30)
    Compatible with all existing Welch Allyn 3.5 V power sources
    Look for the traditional "flat-top" design you've come to trust

    The following steps will help the physician obtain satisfactory results:


    For examination of the right eye, sit or stand at the patient’s right side.


    Select -0-on the illuminated lens dial of the ophthalmoscope and start with small aperture.


    Take the ophthalmoscope and start in the right hand and hold it vertically in front of your own right eye with the light beam directed toward the patient and place your right index finger on the edge of the lens dial so that you will be able to change lenses easily if necessary.


    Dim room lights. Instruct the patient to look straight ahead at a distant object.


    Position the ophthalmoscope about 6 inches (15cm) in front and slightly to the right (25°) of the patient and direct the light beam into the pupil. A red reflex should appear as you look through the pupil.


    Rest the left hand on the patient’s forehead and hold the upper lid of the eye near the eyelashes with the thumb. While the patient holds his fixation on the specified object, keep the reflex in view and slowly move toward the patient.

    The optic disc shouldcome into view when you are about 11/2 to 2 inches (3-5cm) from the patient. If it is not focused clearly, rotate lenses into the aperture with your index finger until the optic disc is as clearly visible as possible.

    The hyperopic, or far-sighted, eye requires more ‘plus’(black numbers) sphere for clear focus of the fundus; the myopic, or nearsighted, eye requires minus (red numbers) sphere for clear focus.
    Now examine thedisc for clarity ofoutline, color,elevation andcondition of thevessels.

    Follow each vessel as farto the periphery asyou can. To locate the macula, focus on the disc, then move the light approximately 2 disc diameters temporally. You may also have the patient look at the light of the ophthalmoscope, which will automatically place the macula in full view. Examine for abnormalities in the macula area. The red-free filter facilitates viewing of the center of the macula, or the fovea.


    To examine the extreme periphery, instruct the patient to:



    a) look up for examination of the superior retina
    b) look down for examination of the inferior retina
    c) look temporally for examination of the temporal retina
    d) look nasally for examination of the nasal retina.
    This routine will reveal almost any abnormality that occurs in the fundus.
    To examine the left eye, repeat the procedure outlined above except that you hold the ophthalmoscope in the left hand, stand at the patient’s left side and use your left eye.



    Share your knowledge of this product. Be the first to write a review »



    Hospital And Physician Supplies > Equipment & Furnishings > Equipment > Exam & Diagnostic > Welch Allyn Diagnostic Sets
    Hospital And Physician Supplies > Equipment & Furnishings > Equipment > Exam & Diagnostic

    Get Connected:

    Copyright ©  Devine Medical. All Rights Reserved.
    Social Tab
    Are you a fan of Devine Medical?
    :like>
    Hide This Bar

    Twitter Feed

    Facebook Feed

    What Our Customers are Saying

    " Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nullam sed augue eget dui pellentesque sodales. Pellentesque habitant morbi "

    -Customer Name

    " Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nullam sed augue eget dui pellentesque sodales. Pellentesque habitant morbi "

    -Customer Name

    " Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nullam sed augue eget dui pellentesque sodales. Pellentesque habitant morbi "

    -Customer Name read more

    Found a lower price? Let us know. Although we can't match every price reported, we'll use your feedback to ensure that our prices remain competitive.

    Where did you see a lower price?

    DD: YY:

    Address

    • Devine Medical Supplies
    • 14749 Carmentita Road
    • Norwalk, CA 90650

    Email

    Phone & Fax


    • Fax:(562) 232-4091

    Please fill out following form and submit .We will email you back Estimate Invoice with shipping for your approval with payment instructions.

    • Product CodeItem nameQuantity

    Shipping Address

    We accept :Credit Card/Paypal/Wire Transfer

    Address

    • Devine Medical Supplies
    • 14749 Carmentita Road
    • Norwalk, CA 90650

    Email

    Phone & Fax

    • Fax:(562) 232-4091

    Please fill out following form and submit for volume pricing

    • Product CodeItem NameQuantity

    Shipping Address

    We accept : Credit Card/Paypal/Wire Transfer/ Purchase Order

    Purchase Order only for govt and B2B

    Address

    • Devine Medical Supplies
    • 14749 Carmentita Road
    • Norwalk, CA 90650

    Email

    Phone & Fax


    • Fax:(562)232-4091